Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Audiol., Commun. res ; 27: e2649, 2022. tab
Article in Portuguese | LILACS | ID: biblio-1383888

ABSTRACT

RESUMO Objetivo Analisar comparativamente os alvos prescritos pelas regras NAL (National Acoustic Laboratories) não lineares com a resposta da prótese auditiva obtida por meio das mensurações com microfone-sonda no ajuste de uso efetivo, de acordo com o grau da perda auditiva. Método Participaram do estudo 67 usuários experientes de próteses auditivas. Todos foram reavaliados quando compareceram às sessões de acompanhamento periódico. Nesse momento, realizou-se avaliação audiológica, registrando-se as horas de uso do dispositivo e realizando-se a resposta com prótese auditiva (REAR - Real Ear Aided Response). Resultados Observou-se que 80% das próteses auditivas de todos os grupos atingiram a faixa analisada, com exceção do grupo de perda moderada. Também foi realizada a análise da porcentagem de orelhas cuja resposta com prótese auditiva estivesse em ±5 dB para as frequências baixas e ±8 dB nas altas frequências e observou-se que menos de 80% dos ajustes atingiram esta faixa. Intervalos de confiança foram construídos para verificar a faixa de adaptação de preferência dos usuários experientes. Conclusão A faixa de ±10 dB demonstra ser a de preferência dos usuários. Porém, para usuários experientes, sugere-se que a faixa de adaptação encontre-se na faixa de ±3 nas frequências baixas e médias e ±7 na região de altas frequências.


ABSTRACT Purpose To compare the targets prescribed by the non-linear NAL with the real ear aided response - REAR obtained through probe microphone in the setting of effective use according to the degree of hearing loss. Methods 67 experienced hearing aid users participated in the study. All were reassessed when attending follow-up sessions. At that moment, they were asked whether they had any complaints with respect to the amplification. An audiological evaluation was performed, the hours of use of the device were recorded and the new probe microphone measurement was taken. Results The percentage of ears with REAR within ± 10dB of the prescriptive target was verified. It was observed that 80% of the hearing aids of all groups reached the analyzed range, with the exception of the moderate hearing loss group. We also performed the analysis of the percentage of ears whose hearing aid response was within ± 5 dB for the low frequencies and ± 8 dB for the high frequencies, and it was observed that less than 80% of the adjustments reached this range. Confidence intervals were constructed to verify the preference fit to target of experienced users. Conclusion The range of ±10dB proves to be the users' preference. For experienced users, it is suggested that the adaptation phase be found in the range of ±3 in the low and medium frequencies and ±7 in the high frequency region


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Persons With Hearing Impairments/rehabilitation , Hearing Aids , Hearing Loss/rehabilitation , Correction of Hearing Impairment , Speech Perception , Signal Processing, Computer-Assisted , Equipment Design
SELECTION OF CITATIONS
SEARCH DETAIL